Mandatory Compliance by 1 January 2027:
  • All dwellings must have interconnected photoelectric smoke alarms. ​
Smoke Alarm Specifications:
  • Must be photoelectric and comply with AS 3786–2014.
  • Must not contain ionisation sensors.
  • Must be less than 10 years old.
  • Must operate when tested.
  • Must be interconnected (wired or wireless) so all alarms activate simultaneously. ​
Installation Locations:
  • In each bedroom.
  • In hallways connecting bedrooms to the rest of the dwelling.
  • If no hallway, between bedrooms and other parts of the storey.
  • On each storey without bedrooms, at least one alarm in the most likely path to exit. ​
Power Supply Requirements:
  • Hardwired to mains power with a backup battery.
  • Or powered by a non-removable 10-year battery.
  • Existing hardwired alarms must be replaced with hardwired photoelectric alarms. ​
Specific Deadlines:
  • From 1 January 2017: Applies to new or substantially renovated dwellings.
  • From 1 January 2022: Applies to dwellings being sold or leased.
  • From 1 January 2027: Applies to all other dwellings. ​
Maintenance Responsibilities:
  • Landlords must test and clean smoke alarms within 30 days before a tenancy starts or is renewed.
  • Tenants must test and clean alarms at least once every 12 months.
  • Non-functioning alarms must be replaced immediately. ​
Installation Guidelines:
  • Install on ceilings where practicable.
  • Avoid placement within 300mm of corners or light fittings, and within 400mm of air-conditioning vents or ceiling fan blades. ​